<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet type="text/xsl" href="style/detail_T.xsl"?>
<bibitem type="C">   <ARLID>0369540</ARLID> <utime>20240103200055.2</utime><mtime>20120120235959.9</mtime>         <title language="eng" primary="1">Monte Carlo simulation of PET images for injection dose optimization</title>  <specification> <page_count>6 s.</page_count> </specification>   <serial><ARLID>cav_un_epca*0371893</ARLID><ISBN>978-0-415-68395-1</ISBN><title>Computational Vision and Medical Image Processing: VipIMAGE 2011</title><part_num/><part_title/><page_num>1-6</page_num><publisher><place>London</place><name>Taylor and Francis</name><year>2011</year></publisher><editor><name1>Manuel</name1><name2>J.</name2></editor><editor><name1>Tavares</name1><name2>R. S.</name2></editor><editor><name1>Jorge</name1><name2>N.</name2></editor></serial>    <keyword>positron emission tomography</keyword>   <keyword>Monte Carlo simulation</keyword>   <keyword>biological system modeling</keyword>   <keyword>image quality</keyword>    <author primary="1"> <ARLID>cav_un_auth*0101071</ARLID> <name1>Boldyš</name1> <name2>Jiří</name2> <full_dept language="cz">Zpracování obrazové informace</full_dept> <full_dept language="eng">Department of Image Processing</full_dept> <department language="cz">ZOI</department> <department language="eng">ZOI</department> <institution>UTIA-B</institution> <full_dept>Department of Image Processing</full_dept>  <fullinstit>Ústav teorie informace a automatizace AV ČR, v. v. i.</fullinstit> </author> <author primary="0"> <ARLID>cav_un_auth*0273046</ARLID> <name1>Dvořák</name1> <name2>Jiří</name2> <full_dept language="cz">Zpracování obrazové informace</full_dept> <full_dept>Department of Image Processing</full_dept> <department language="cz">ZOI</department> <department>ZOI</department> <institution>UTIA-B</institution> <full_dept>Department of Image Processing</full_dept>  <fullinstit>Ústav teorie informace a automatizace AV ČR, v. v. i.</fullinstit> </author> <author primary="0"> <ARLID>cav_un_auth*0214731</ARLID> <name1>Bělohlávek</name1> <name2>O.</name2> <country>CZ</country>  </author> <author primary="0"> <ARLID>cav_un_auth*0278597</ARLID> <name1>Skopalová</name1> <name2>M.</name2> <country>CZ</country>  </author>   <source> <url>http://library.utia.cas.cz/separaty/2012/ZOI/boldys-monte carlo simulation of pet images for injection dose optimization.pdf</url> </source>        <cas_special> <project> <project_id>1M0572</project_id> <agency>GA MŠk</agency> <country>CZ</country> <ARLID>cav_un_auth*0001814</ARLID> </project> <research> <research_id>CEZ:AV0Z10750506</research_id> </research>  <abstract language="eng" primary="1">When a patient is examined by positron emission tomography, radiotracer dose amount has to be determined. However, the rules used nowadays do not correspond with practical experience. Slim patients are given unnecessary  amount of radiotracer and obese patients would need more activity to produce images of sufficient  quality. We have built a model of a particular PET scanner and approximated human trunk, which is our region  of interest, by a cylindrical model with segments of liver, outer adipose tissue and the rest. We have performed  Monte Carlo simulations of PET imaging using the GATE simulation package. Under reasonably simplifying  assumptions and for special parameters, we have developed curves, which recommend amount of injected activity  based on body parameters to give PET images of constant quality. The dependence qualitatively differs  from the rules used in clinical practice nowadays and the results indicate potential for improvement</abstract>  <action target="WRD"> <ARLID>cav_un_auth*0277448</ARLID> <name>VipIMAGE 2011 - third ECCOMAS thematic conference on computational vision and medical image processing</name>  <place>Olhao, Algarve</place> <dates>12.10.2011-14.10.2011</dates>  <country>PT</country> </action>    <reportyear>2012</reportyear>  <RIV>BD</RIV>      <num_of_auth>4</num_of_auth>   <permalink>http://hdl.handle.net/11104/0203576</permalink>        <arlyear>2011</arlyear>       <unknown tag="mrcbU63"> cav_un_epca*0371893 Computational Vision and Medical Image Processing: VipIMAGE 2011 978-0-415-68395-1 1 6 London Taylor and Francis 2011 </unknown> <unknown tag="mrcbU67"> Manuel J. 340 </unknown> <unknown tag="mrcbU67"> Tavares R. S. 340 </unknown> <unknown tag="mrcbU67"> Jorge N. 340 </unknown> </cas_special> </bibitem>