bibtype |
V -
Research Report
|
ARLID |
0312465 |
utime |
20240103190432.2 |
mtime |
20081006235959.9 |
title
(primary) (cze) |
Analýza radiologických důsledkůpřípadu vystřelení havarijní regulační kazety v JE Dukovany |
EGP-5014-F-080065
publisher |
place |
Praha |
name |
ÚJV Řež, divize ENERGOPROJEKT |
pub_time |
2008 |
|
specification |
|
title
(eng) |
Analysis of radiological consequences of accidental control assembly ejection for JE Dukovany |
keyword |
EJECTION ACCIDENT |
keyword |
CONTROL ASSEMBLY |
author
(primary) |
ARLID |
cav_un_auth*0241144 |
name1 |
Junek |
name2 |
V. |
country |
CZ |
|
author
|
ARLID |
cav_un_auth*0021085 |
name1 |
Pechová |
name2 |
E. |
country |
CZ |
|
author
|
ARLID |
cav_un_auth*0241145 |
name1 |
Kelemen |
name2 |
R. |
country |
CZ |
|
author
|
ARLID |
cav_un_auth*0101176 |
name1 |
Pecha |
name2 |
Petr |
institution |
UTIA-B |
full_dept |
Department of Adaptive Systems |
fullinstit |
Ústav teorie informace a automatizace AV ČR, v. v. i. |
|
cas_special |
project |
project_id |
GA102/07/1596 |
agency |
GA ČR |
country |
CZ |
ARLID |
cav_un_auth*0227611 |
|
research |
CEZ:AV0Z10750506 |
abstract
(cze) |
Výpočty radiologických důsledků nehody způsobené vystřelením řídící havarijní kazety. Únik aktivního chladiva z primárního okruhu do sekundárního okruhu a dále řešení úniku aktivní páry přes PSA do atmosféry. Vypočtené dávky záření jsou srovnávány s limity stanovenými vládním nařízenímy. |
abstract
(eng) |
Calculation of radiological consequences caused by accidental ejection of reactor control assembly. Release of radioactivity from primary circuit and its penetration into secondary circuit. Estimation of final release into living environment through PSA devices. Calculation of doses of irradiation and their comparison with limits from governmental regulations. |
reportyear |
2009 |
RIV |
AQ |
permalink |
http://hdl.handle.net/11104/0163525 |
arlyear |
2008 |
mrcbU10 |
2008 |
mrcbU10 |
Praha ÚJV Řež, divize ENERGOPROJEKT |
|